Cannot find the part you're looking for? Click here!

Products

Filters

12 products found

Categories
Capacitance (µF)
Tolerance
KVAR
  • N/A
Voltage AC
  • N/A
Voltage DC
ESR
  • N/A
Application
Termination
Operating Temperature
Product Code Image Data Sheet Attributes
X620 1 5 100

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 100V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 6
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.276" T x 0.472" H x 0.492" L
  • Dimension mm: 7.0mm x 12.0mm x 12.5mm
X620 1 5 250

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 250V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 7
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.315" T x 0.630" H x 0.728" L
  • Dimension mm: 8.0mm x 16.0mm x 18.5mm
X620 1 5 400

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 400V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 8
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.335" T x 0.728" H x 1.024" L
  • Dimension mm: 8.5mm x 18.5mm x 26.0mm
X620 1 5 630

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 630V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 7
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.531" T x 0.866" H x 1.220" L
  • Dimension mm: 13.5mm x 22.0mm x 31.0mm
X621 1 5 100

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 100V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 3
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.295" T x 0.551" H x 0.709" L
  • Dimension mm: 7.5mm x 14.0mm x 18.0mm
X621 1 5 250

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 250V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 4
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.354" T x 0.630" H x 1.024" L
  • Dimension mm: 9.0mm x 16.0mm x 26.0mm
X621 1 5 400

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 400V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 5
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.472" T x 0.787" H x 1.220" L
  • Dimension mm: 12.0mm x 20.0mm x 31.0mm
X621 1 5 630

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 630V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 7
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.689" T x 1.102" H x 1.220" L
  • Dimension mm: 17.5mm x 28.0mm x 31.0mm
X624(D3) 1 5 100

Data Sheet: X624

  • Application: DC Filter, Sample Hold
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 100V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 3
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Dielectric Material: Polyester - Metallized
  • Case: Preformed Case with Epoxy Fill
  • Termination: Solid Wire
  • Dimension inches: 0.295" T x 0.531" H x 0.709" L
  • Dimension mm: 7.5mm x 13.5mm x 18.0mm
X624(E3) 1 5 250

Data Sheet: X624

  • Application: DC Filter, Sample Hold
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 250V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 4
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Dielectric Material: Polyester - Metallized
  • Case: Preformed Case with Epoxy Fill
  • Termination: Solid Wire
  • Dimension inches: 0.335" T x 0.669" H x 1.043" L
  • Dimension mm: 8.5mm x 17.0mm x 26.5mm
X624(F1) 1 5 400

Data Sheet: X624

  • Application: DC Filter, Sample Hold
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 400V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 5
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Dielectric Material: Polyester - Metallized
  • Case: Preformed Case with Epoxy Fill
  • Termination: Solid Wire
  • Dimension inches: 0.433" T x 0.787" H x 1.260" L
  • Dimension mm: 11.0mm x 20.0mm x 32.0mm
X626 1 5 63

Data Sheet: X626

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 63V
  • Operating Temperature: -40 °C to +85 °C
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.217" T x 0.394" H x 0.413" L
  • Dimension mm: 5.5mm x 10.0mm x 10.5mm
Product Code Image Data Sheet Attributes
X620 1 5 100

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 100V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 6
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.276" T x 0.472" H x 0.492" L
  • Dimension mm: 7.0mm x 12.0mm x 12.5mm
X620 1 5 250

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 250V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 7
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.315" T x 0.630" H x 0.728" L
  • Dimension mm: 8.0mm x 16.0mm x 18.5mm
X620 1 5 400

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 400V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 8
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.335" T x 0.728" H x 1.024" L
  • Dimension mm: 8.5mm x 18.5mm x 26.0mm
X620 1 5 630

Data Sheet: X620

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 630V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 7
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.531" T x 0.866" H x 1.220" L
  • Dimension mm: 13.5mm x 22.0mm x 31.0mm
X621 1 5 100

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 100V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 3
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.295" T x 0.551" H x 0.709" L
  • Dimension mm: 7.5mm x 14.0mm x 18.0mm
X621 1 5 250

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 250V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 4
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.354" T x 0.630" H x 1.024" L
  • Dimension mm: 9.0mm x 16.0mm x 26.0mm
X621 1 5 400

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 400V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 5
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.472" T x 0.787" H x 1.220" L
  • Dimension mm: 12.0mm x 20.0mm x 31.0mm
X621 1 5 630

Data Sheet: X621

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 630V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 7
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.689" T x 1.102" H x 1.220" L
  • Dimension mm: 17.5mm x 28.0mm x 31.0mm
X624(D3) 1 5 100

Data Sheet: X624

  • Application: DC Filter, Sample Hold
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 100V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 3
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Dielectric Material: Polyester - Metallized
  • Case: Preformed Case with Epoxy Fill
  • Termination: Solid Wire
  • Dimension inches: 0.295" T x 0.531" H x 0.709" L
  • Dimension mm: 7.5mm x 13.5mm x 18.0mm
X624(E3) 1 5 250

Data Sheet: X624

  • Application: DC Filter, Sample Hold
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 250V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 4
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Dielectric Material: Polyester - Metallized
  • Case: Preformed Case with Epoxy Fill
  • Termination: Solid Wire
  • Dimension inches: 0.335" T x 0.669" H x 1.043" L
  • Dimension mm: 8.5mm x 17.0mm x 26.5mm
X624(F1) 1 5 400

Data Sheet: X624

  • Application: DC Filter, Sample Hold
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 400V
  • Operating Temperature: -40 °C to +85 °C
  • IPeak: 5
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Dielectric Material: Polyester - Metallized
  • Case: Preformed Case with Epoxy Fill
  • Termination: Solid Wire
  • Dimension inches: 0.433" T x 0.787" H x 1.260" L
  • Dimension mm: 11.0mm x 20.0mm x 32.0mm
X626 1 5 63

Data Sheet: X626

  • Application: Filtering, General Purpose, Instrumentation
  • Capacitance (µF): 1
  • Tolerance: ±5%
  • Voltage Rating - DC: 63V
  • Operating Temperature: -40 °C to +85 °C
  • Lifecycle @ Rated Temp & Voltage: 60,000 hrs
  • Construction: non-inductive wound metallized polyester film
  • Mounting Type: Through Hole
  • Dielectric Material: Polyester - Metallized
  • Case: Epoxy Dipped
  • Termination: Solid Wire
  • Dimension inches: 0.217" T x 0.394" H x 0.413" L
  • Dimension mm: 5.5mm x 10.0mm x 10.5mm